Chromatography Syringes
Syringes for manual or autosampler injections, in a variety of sizes, needle gauges, point styles, and terminations; includes electronic and manual gas tight syringes, HPLC general syringes, and replacement parts and accessories. Choose from leading brands for analytical gas and liquid syringes. Specialty syringes designed for unique applications are also available.
Filtered Search Results
Restek™ Hamilton™ Micro-Volume Positive Displacement Syringe, 2.0μL
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Use these syringes for accurate, high precision injections. Restek™ Hamilton™ Micro-Volume Positive Displacement Syringes are designed to contain the sample in the needle with full plunger displacement, ensuring no dead volume.
Hamilton™ 1700 Series Gastight™ Gel Loading Syringes, 10uL
Syringes are designed to work for multiplex DNA sequencing applications
| Needle Point Number | 3 |
|---|---|
| Max. Temperature (English) | 122°F |
| Volume (Metric) | 10 μL |
| Min. Temperature (English) | 50°F |
| Max. Temperature (Metric) | 50°C |
| For Use With (Application) | Designed to work for multiplex DNA sequencing applications |
| Autoclavable | Not Autoclavable |
| Sterility | Sterile |
| Max. Pressure | 1000 psi |
Hamilton™ 1800 Series Gastight™ Fixed-Needle Syringes
Reinforced plunger version of the 1700 series syringes is ideal for dispensing volumes from 1 μL up to 500 μL.
| Needle Point Number | 2 |
|---|---|
| Quantity | 1/Pk. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 50°C |
| For Use With (Application) | Dispensing volumes from 1μL up to 500μL |
| Max. Pressure | 1000 psig (68.9 bar) |
| Product Type | Gastight, Cemented Needle |
| Connection Type | Cemented |
| Max. Temperature (English) | 122°F |
| Needle Point Style | 2 |
| Length (English) Needle | 2 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
Restek™ Presents SGE Gas-Tight Syringes Fitted with Luer-lock Valve
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Ideal for sample storage and transportation.
| Includes | Luer-lock valve |
|---|---|
| Product Type | SGE Gas-Tight Syringe Fitted with Luer lock Valve |
| Quantity | Ea. |
| For Use With (Application) | For sample storage and transportation. |
| Needle Point Number | 2 |
|---|---|
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 50°C |
| For Use With (Application) | Ideal for despensing both liquids and gases |
| Product Type | Gastight Syringe |
| Diameter (Metric) Outer | 7.75 mm |
| Max. Temperature (English) | 122°F |
| Diameter (English) Outer | 0.305 in. |
| Needle Point Style | Sharp, Bevel, Curved, Non-coring |
| Diameter (Metric) Outer Needle | 0.72 mm |
| Length (English) Needle | 2 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Diameter (English) Outer Needle | 0.028 in. |
Hamilton™ Modified 7000 Microliter™ Syringes
This series of syringes is ideal for dispensing volumes from 0.05 μL up to 5 μL. The 7000 series is the only zero dead volume syringe. The fine gauge plunger wire travels to the tip of the needle ensuring that all solvent is expelled from the needle.
| Product Type | General Purpose Syringe |
|---|---|
| Diameter (Metric) Outer | 7.82 mm |
| Connection Type | Knurled Hub, Removable |
| Max. Temperature (English) | 239°F |
| Diameter (English) Outer | 0.3 in. |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Length (English) Needle | 2.75 in. |
| Max. Temperature (Metric) | 115°C |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Diameter (English) Outer Needle | 0.02 in. |
Hamilton™ Constant Rate-700 HPLC Syringes & Replacement Parts
Syringes are designed to delive reasy, reproducible injection of liquid samples into an injector on HPLC instrumentation. The CR-700 standardizes three major variables: sample volume, rate of injection, and depth of needle penetration. Even when operated by different technicians, the CR-700 provides reproducibility of +1% of the total syringe volume in routine procedures.
| For Use With (Equipment) | HPLC Injection Valves |
|---|---|
| Needle Point Style | Blunt |
| Length (English) Needle | 2 in. |
Restek™ Presents SGE Gas-Tight Syringes for Agilent 7673/7683/6850
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For Agilent 7673, 7683, 7693A, and 6850 Autosamplers.
| For Use With (Equipment) | Agilent 7673, 7683, 6850 Autosampler |
|---|---|
| Product Type | SGE Gas-Tight Syringes for Agilent Autosamplers |
| Volume (Metric) | 10 μL |
| Needle Point Style | Cone |
| Quantity | Ea. |
| Material | PTFE (Tip) |
| Length (English) Needle | 1.6 in. |
Hamilton™ 700/700 Microliter™: KH Termination
Syringes have a built-in syringe guide, designed to prevent the plunger from bending and pulling out of the syringe
| Needle Point Number | 3 |
|---|---|
| Length (Metric) | 70 mm |
| Length (English) | 2.75 in. |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | Designed for liquid sampling to achieve the highest level of accuracy and precision possible, for use with HPLC injection valves and for sample pipetting |
| Max. Pressure | 6000 psi |
| Product Type | MicroliterGeneral Purpose Syringe |
| Connection Type | Knurled Hub |
| Max. Temperature (English) | 239°F |
| Needle Point Style | Blunt |
| Length (English) Needle | 2.75 in. |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
Hamilton™ 600 Microliter™ Syringes
The 600 series syringes are a half stroke version of the original 700 series syringes. This series of syringes is ideal for dispensing volumes from 0.25 μL up to 5 μL. The 600 series is often used in applications that require one handed operation because of the short stroke length and the reinforced plunger.
| Needle Point Number | 3 |
|---|---|
| Length (Metric) | 51 mm |
| Length (English) | 2 in. |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | Designed for applications that require one-handed operation because of the short stroke length and the reinforced plunger |
| Max. Pressure | 2000 psi |
| Diameter (Metric) Inner Needle | 0.13 mm |
| Product Type | Microliter Syringe |
| Diameter (Metric) Outer | 6.6 mm |
| Connection Type | Removable |
| Max. Temperature (English) | 239°F |
| Diameter (English) Outer | 0.26 in. |
| Needle Point Style | Blunt |
| Diameter (Metric) Outer Needle | 0.71 mm |
| Length (English) Needle | 2 in. |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Needle Gauge | 22s G |
| Diameter (English) Outer Needle | 0.028 in. |
| Diameter (English) Inner Needle | 0.005 in. |
Restek™ 1700 Series Manual Gas Tight Syringes (Hamilton)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Restek™ Presents Hamilton Economical Microliter Liquid-Type Syringes for Rheodyne and Valco Valve
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For Rheodyne and Valco valves.
| Needle Point Number | 3 |
|---|---|
| Diameter (Metric) Inner Needle | 0.15 mm |
| For Use With (Equipment) | Rheodyne and Valco Valves |
| Product Type | Hamilton Economical Microliter Liquid-Type Syringe |
| Connection Type | Cemented |
| Needle Point Style | 3 |
| Quantity | Ea. |
| Diameter (Metric) Outer Needle | 0.72 mm |
| Length (English) Needle | 2 in. |
| Needle Gauge | 22s G |
| Diameter (English) Outer Needle | 0.028 in. |
| Diameter (English) Inner Needle | 0.006 in. |
Restek™ Presents SGE Reinforced Plunger Microliter Volume Syringes
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Reinforcing extends the life of fragile, small diameter plungers.
| Needle Point Number | 2 |
|---|---|
| Diameter (Metric) Inner Needle | 0.26 mm |
| Length (Metric) | 50 mm |
| Product Type | SGE Reinforced Plunger Microliter Syringes |
| Length (English) | 2 in. |
| Needle Point Style | 2 |
| Quantity | Ea. |
| Diameter (Metric) Outer Needle | 0.46 mm |
| Length (English) Needle | 1.9 in. |
| Needle Gauge | 26 G |
| Diameter (English) Outer Needle | 0.018 in. |
| Diameter (English) Inner Needle | 0.0102 in. |
Restek™ Presents Hamilton Standard Microliter Syringes for Agilent 7673/7683/6850 GCs, 0.5 μL
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For Agilent 7673, 7683, 7693A, and 6850 Autosamplers.
| For Use With (Equipment) | Agilent 7673, 7683, 7693A and 6850 Autosamplers |
|---|---|
| Product Type | Hamilton Standard Microliter Syringes for Agilent Autosamplers |
| Connection Type | Autosampler Removable |
| Volume (Metric) | 0.5 μL |
| Model | 7000.5 |
| Quantity | Ea. |
| Length (English) Needle | 1.71 in. |
| Length (Metric) Needle | 43.4 mm |